Range: CYCLA
All sectors


Water treatment and recycling

At Montanier , our water treatment system allows us to recycle up to 80-85% of wash water , contributing to sustainable and economical resource management. To achieve this performance, our R&D team designed a three-stage :

1. Pretreatment (underground installation)
We begin with a settling tank operating on the principle of sedimentation. This method efficiently separates solid particles from the water thanks to the difference in density. An oil separator completes the system to remove floating pollutants and protect the rest of the treatment process.

2. Secondary Treatment (Underground Installation)
Secondary treatment relies on a 20 m³ lift tank with an aerobic biological reactor . This reactor contains microorganisms that consume dissolved pollutants through oxygen injection. A recirculation pump recovers the biological sludge and returns it to the settling tank, thus ensuring continuous optimization of the treatment process .

3. Tertiary Treatment (Above-Ground Installation)
Tertiary treatment includes a filtration skid that improves the quality of the recycled water before it is stored. The filtered water is then directed to a buffer tank , ensuring a stable supply of high-quality treated water .

Our processing system is sized according to the number of buses and coaches washed daily , guaranteeing efficient recycling adapted to your needs.

Water treatment
Technical table for treatment and recycling
  • Key points
arrow icon

Your water treatment follows you: The CYCLA FE provides a recycling solution for your existing or new washing solutions.

screwdriver and wrench icon

The entire recycling system is placed in a mobile container, heated and protecting the equipment from the elements.

water drop icon

Several levels of filtration: separation of sludge and hydrocarbons, then finer and automated filtration.

water spray icon

Return pump to your washing and rinsing water tanks or networks (optional).

Wave icon

Continuous disinfection of stored water to prevent bacterial growth: UV lamp, activated carbon, antibacterial agent.

innovation icon

Options: Rainwater harvesting, rinsing water, water softener, lift pump, BOM wash area…